Pub.# OM17-PRC
6-6
10. Population Monitor rate does not match Veris Console.
-Make certain that PF3000 and Veris Console agree. If not, see
Troubleshooting step 3 above.
-Re-check calibration number, and re-run calibration procedure if necessary
-Re-check planter monitor settings: calibration number, row spacing, number
of rows, swath width, seed, etc.
-When planting small size seeds and/or at high rates, if population monitor
consistently indicates a lower population than the Veris Console, contact
monitor manufacturer for performance specs for that application.