Veris-technologies OpticMapper - Application Note Manual do Utilizador

Consulte online ou descarregue Manual do Utilizador para Equipamento Veris-technologies OpticMapper - Application Note. Veris Technologies OpticMapper - Application Note User Manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 5
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 0
Application Note: OpticMapper
Proper Mapping Techniques
1. Equipment Testing. Before mapping, perform equipment tests using electronics test
load and reference block, as recommended by Operations Manual.
2. Recognize Effects of Soil Condition. In order to generate high quality OM data, it’s
crucial to understand that field history, soil conditions, and equipment settings can affect
estimations of OM from OpticMapper measurements. The most important consideration
is soil moisture: moist soil and organic matter are both darker in color than dry soil and
low OM, which could lead to confusing and erroneous estimations of soil organic matter.
Effective OM field mapping requires consistent moisture levelsof course soils have
natural differences based on soil water-holding capacity--sand will have less moisture,
clay more. What are critical to prevent are management-related moisture
inconsistencies. These can be caused by:
a) A field having two or more moisture conditions, due to tillage, cropping, or irrigation
differences (Figure 1). To avoid these situations, treat each condition as a separate
field: map differing conditions on separate files, and make sure both conditions are
represented with calibration samples.
Figure1. Moisture variation between two fields mapped as one
b) Adjustment of OpticMapper during mappingchanging depth or down-pressure
which causes sensing depth to change (Figure 2). If in-field adjustments are required,
Vista de página 0
1 2 3 4 5

Resumo do Conteúdo

Página 1 - Proper Mapping Techniques

Application Note: OpticMapper Proper Mapping Techniques 1. Equipment Testing. Before mapping, perform equipment tests using electronics test load an

Página 2

begin a new file and make sure both conditions are represented with calibration samples. Figure 2. Data shift due to adjustment of OpticMapper durin

Página 3

Figure 4. Mapping at a slight angle to main fieldwork pattern Note: Inaccurate estimations of organic matter due to soil moisture conditions can hav

Página 4

- if not possible to map at angle, maintain soil and residue consistency for OpticMapper row unit; avoid wheel tracks and heavy residue strips if poss

Página 5

Figure 6. Examples of proper sample selection (left) and improper (right). Problems are: samples do not represent full field—none north of waterwa

Comentários a estes Manuais

Sem comentários